Rane ECM 64 handleiding
Handleiding
Je bekijkt pagina 21 van 26

Manual-21
Hybrid Parameter List (HPL)
Hybrid Command Data Description
0 Dial DTMF Number (char) string Null terminated ASCII string, 20 (char) max
1 Dial Stored Number 1-6 Dial stored number (1 – 6)
2 Off Hook 1/0 1= Off Hook / 0 = On Hook
A ‘,’ within the DTMF number inserts a 1 second delay.
A non-digit within the DTMF number is allowed for separation (425.355.6000).
For Rev 1.2 or greater there are added special function DTMF dialing operators:
Operator
!1 Performs a 100 ms Flash Hook
!2 Performs a 500 ms Flash Hook
!3 Places the caller on Hold
!4 Removes the caller from Hold
Send Hybrid Command (92 hex)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $XX (where $XX = number of data bytes to follow including checksum)
Transmit $92 (command code)
Transmit Hybrid command
Transmit Data
Transmit the checksum
Get COMSTAT
Send MRP Table (93 hex)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $12 (where $12 = number of data bytes to follow including checksum)
Transmit $93 (command code)
Transmit 16 byte table
Transmit the checksum
Get COMSTAT
Get OPSTAT (00 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $02 (where $02 = number of data bytes to follow including checksum)
Transmit $00 (command code)
Transmit $FE (checksum)
Get STATUS
Get Checksum
Get COMSTAT
Bekijk gratis de handleiding van Rane ECM 64, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Rane |
Model | ECM 64 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3260 MB |