Radial Engineering Tossover handleiding

11 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 6 van 11
Tossover™ 500 Series Module
True to the Music
®
Radial Engineering Ltd.
4
USING THE FILTERS
The Tossover is designed to work either as a frequency divider or a lter that can be used in
three different ways:
• High-pass lter (HPF): Enables the high frequencies to pass while ltering out the lows
• Low-pass lter (LPF): Enables the low frequencies to pass while ltering out the highs
• Band-pass lter (BPF): Filters out the highs and lows when both lters are turned on
The difference between a frequency divider and a lter really comes down to application. A
lter is used to warm up or clean up a track like a subtle equalizer while a frequency divider is
used to separate part of the signal and send it along to another device for further processing.
The BOTH switch determines if the lters will be used separately or together to create band
pass lter. When depressed, the signal passes through the low pass lter and then, through
the high pass lter. In this mode, the amplitude or output level is set by the high-pass lter
control.
REAR
INPUT
REAR
OUTPUT
AMPLITUDE
LOW-PASS
FILTER
HIGH-PASS
FILTER
When used individually with the BOTH switch disengaged, you can select which of the two
lters outputs will be sent to the XLR output on your 500 series rack by moving the mini
toggle switch in the desired position. If you are equipped with a Workhorse, this toggles the
output between the XLR and the Omniport.
REAR
INPUT
REAR
OUTPUT
AMPLITUDE
LOW OR HIGH
FILTER
Setting the frequency and amplitude
The lter’s FREQUENCY control sets the cut-off point where attenuation begins. In the case
of the high-pass lter all frequencies BELOW the cut-off point are attenuated. Similarly, the
low-pass lter removes all frequencies ABOVE the cut-off.
-
3
5
+5
-
3
0
-
2
5
-
2
0
-
1
5
-
1
0
-
5
0
-
3
5
+5
-
3
0
-
2
5
-
2
0
-
1
5
-
1
0
-
5
0
140Hz
7kHz
1200Hz450Hz
140Hz
7kHz
1200Hz450Hz
250Hz
80Hz
900Hz
4kHz
250Hz
80Hz
900Hz
4kHz
LOW-PASS FREQUENCY HIGH-PASS FREQUENCY
While auditioning your voice or program music through the Tossover turn on the low-pass
lter, and sweep the FREQUENCY control through its full range. You may need to adjust the
AMPLITUDE control upward to hear the effect as much of the signal gain will be attenuated.
Note that the low-pass AMPLITUDE control is disabled when the BOTH switch is depressed.
In this case the overall output level is set using the high-pass AMPLITUDE control.