Running Redundancy Check (CLU)
Redundancy Check is a maintenance procedure for logical drives in fault-tolerant disk arrays that ensures all
the data matches exactly.
To run Redundancy Check:
1. Main Menu >>
Logical Drive Management
2. Highlight the logical drive you want and press Enter.
3. Highlight
Background Activities
>>
Start Redundancy Check
The redundancy check parameters appear.
• Auto Fix–Correctsinconsistenciesautomatically
• Pause On Error–PausestheRedundancyCheckwhenanerrorisfound
To change a parameter, highlight it and press the backspace toggle between
Yes
and
No
.
4. Highlight
Start
and press Enter.
If necessary, you can pause and resume or stop and restart the Redundancy Check. You can use the
logical drive while Redundancy Check is running.
For Redundancy Check rate, see “Making Background Activity Settings (CLU)” on page 76.
Locating a Logical Drive (CLU)
This feature helps you identify the physical drives assigned to the logical drive you are working with in the CLU.
To locate a logical drive:
1. Main Menu >> Logical Drive Management
2. Highlight the logical drive you want and press Enter.
3. Highlight Locate Logical Drive and press Enter.
The drive carrier status LEDs ash for one minute.
74
Vess A Class Storage Appliance for Video Surveillance Promise Technology
Bekijk gratis de handleiding van Promise Technology VESS A3340S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Promise Technology |
| Model | VESS A3340S |
| Categorie | Bewakingscamera |
| Taal | Nederlands |
| Grootte | 26518 MB |
Caratteristiche Prodotto
| Gewicht | 12900 g |
| Breedte | 410 mm |
| Diepte | 446 mm |
| Hoogte | 88.2 mm |
| Frequentie van processor | 3.6 GHz |