COOLING CIRCUIT MAINTENANCE
3
Although the process described before is
done, it is still possible to have refrigerant
inside the circuit if the dryer is clogged.
Cut the pipe from condenser 5mm from the
5mm
dryer using only orbital tube cutters,the
refrigerant outgoing
and till emission is completed.
This process must last 15 minutes.
Terminalto
becut
Caution:
It is forbidden to take off the pipe by welding method.
Otherwise an explosion occurs due to flammable
refrigerant (R600a/R290) inside the circuit.
Cut the compressor service pipe using
only orbital tube cutters.
Plug in the unit and leave the
compressor running.
4
Low pressure
side process
tube
Check that there is suction from the
service pipe and blow from the
condenser pipe (if there aren’t, the
compressor is fauly).
tube
W i d 15 i il h i
W
a
i
t aroun
d
15
m
i
nutes unt
il
t
h
e
i
nner
pressure is equal to the atmospheric
pressure and the refrigerant emission is
completed.
Terminal to
be cut