REPAIR PROCESS
Page 29
COOLING CIRCUIT MAINTENANCE
REPAIR
PROCESS
Before undertaking any operations concerning the refrigerating equipment, it is ABSOLUTELY NECESSARY to empty the
refrigeration circuit following the instructions given in the following paragraph . The producer disclaims any responsibility in
case of lack of application or partial application of such instructions.
1. Opening of refrigeration circuit
1
Move the product outside (or at least to a well aired area), in order to avoid
stagnations in closed areas of the gas leaking when the circuit is opened
2
- Cut the ca
p
illar
y
tube 5 mm from the
2
p y
dryer
- Plug in the unit, the compressor runs
and the refrigerant flows out.
Leave the compressor running for 5
Leave
the
compressor
running
for
5
minutes, then unplug the unit, gently
shake the compressor , allowing a small
quantity of refrigerant which is
dissolved in oil to be released from the
5mm
frozen oil. After 3 minutes , once again,
plug in the unit and leave the compressor
running for 5 minutes, when the
refrigerant emission is completed,
un
p
lu
g
the unit.
p g
Terminalto
becut