uously until the trigger is released.
The rapid-fire trigger may not be used:
– when moving from one work point to the next for example over stairs, ladders
or scaffolding.
– when sealing boxes or crates.
– when attaching safeties for transport.
Pneumatic staplers that are equiped with contact trigger (for
restricted use) or Rapid fire trigger with trigger safety and labelled
with the symbol “do not use on scaffoldings and ladders” are not
allowed to be used for above mentioned applications.
For optimal tacker operation, dry, filtered and oiled compressed air
is required in sufficient quantities.
If the pressure in the air lines is higher than the maximal admissi-
ble operating pressure of the tacker, a pressure control valve
(pressure limiter) equipped with a downstream pressure relief valve
must be installed in the inlet line to the tacker.
Note: When compressed air is generated using a compressor, the
natural humidity in the air condenses and collects as conden-
sation in the pressure chamber and tubing. This conden-sation is
removed from the system using water collectors. The collectors
must be checked daily and emptied if necessary, otherwise rust
may form in the pneumatic lines and the tacker and result in tool wear.
The compressors must meet all requirements regarding the pressure and suc-
tion capacity (volume flow) for the envisioned use. Excess strain on the com-
pressor or capacities that are too low in function of the tubing lengths (tubes
and hoses) will lead to loss of pressure.
Permanently laid air lines must have an interior diameter of at least 19 mm. In
the case of longer air lines or multiple users, the lines must be strengthened
correspondingly.
The air lines should be sloped (highest point towards the compressor). Install
easily accessible water collectors at the lowest points.
All user air outlets must be built on to the top side of the air lines.
Compressed air outlets that are planned for use with tackers should be
equipped with compressed air maintenance units (i. e. filter, water collectors,
oiler). The oilers must be checked daily and, if necessary, be filled with the
required oil (see TE CHNICAL SPE CIFICATIONS).