Practixx PX-CS15T handleiding
Handleiding
Je bekijkt pagina 45 van 76

w ww.practixx.com
GB
|
45
2. Leave the bleed screw (15) loose during operation.
3. Before you move the log splitter, close the bleed
screw (15) again, since oil can run out otherwise.
Attention!
• When working below 5°C, the device should be idled
for approx. 15 minutes to allow the hydraulic oil to
warm up.
• Before transporting the device, it is essential to tight-
en the bleed screw to prevent oil leakage.
Functional check
Carry out a functional check before every use.
Action Result
Press the control lever
on the right (5) and the
control lever on the left
(18) down.
The splitting wedge (3)
drives down.
Release the right
operating lever (5) or the
left operating lever (18).
The splitting wedge (3)
remains in the selected
position.
Release the control
lever on the right (5) and
the control lever on the
left (18).
Splitting wedge (3)
moves back to the upper
position.
Actuate the stop lever
lever (21).
The splitting wedge (3)
remains in the selected
position.
10.4 Greasing the splitting column (2) (Fig. 1)
m Attention!
Do not run the splitting column dry.
Generously grease the splitting column (2) of the log
splitter before putting it into operation. This process
must be repeated every 5 operating hours.
1. The splitting column (2) must be in the top position.
2. Apply a generous lm of grease or spray oil to the
splitting column (2).
10.5 Switching on/off (Fig. 13)
Note:
Check the function of the on/off switch by switch-
ing it on and off again once before each use.
1. Connect the electrical power connection (34) to
the mains socket.
2. To switch on, press the green button on the on/off
switch (24), the device switches on.
3. To switch off, press the red button on the on/off
switch (24), the device switches off.
4. Disconnect the electrical power connection (34)
from the mains socket when you want to nish work.
10.1 Setting up the log splitter
m Attention!
Risk of injury from the log splitter tipping over. A
toppling log splitter can cause serious injuries and
damage.
Prepare the workplace where the device is to be lo-
cated:
• Create enough space to allow safe, trouble-free
working.
• The device is designed for working on level surfac-
es and must be set up securely on a level and rm
surface.
10.2 Checking the oil level (Fig. 1, 12)
m Attention!
Check the oil level prior to commissioning!
The hydraulic system is a closed system with an oil
tank, oil pump and control valve. There is already oil in
the system when delivered. Check the oil level before
the initial commissioning and regularly before commis-
sioning. An oil level that is too low can damage the oil
pump, rell with oil if necessary.
Note
The splitting column (2) must be retracted before the
check, the device must be level.
1. Unscrew the bleed screw (15).
2. Wipe the oil dipstick (32) with a clean, lint-free cloth.
3. Screw the bleed screw (15) back into the ller neck
until it reaches the stop.
4. Unscrew the bleed screw (15) and read the oil level
in the horizontal position. The oil level must be be-
tween min. and max. at the dipstick (32).
5. If the oil level is too low, top up as described in
section 12.5.
6. Then screw the bleed screw (15) back in.
10.3 Bleeding the hydraulic oil tank (14) (Fig. 12)
m Attention!
Bleed the hydraulic tank before starting the log
splitter.
Note
If the hydraulic tank (14) is not bled, the trapped air will
damage the seals and therefore the log splitter!
1. Before starting work, it is essential to loosen the
bleed screw (15) by two turns to ensure air circula-
tion in the hydraulic oil tank (14).
Bekijk gratis de handleiding van Practixx PX-CS15T, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Practixx |
| Model | PX-CS15T |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |