Posiflex RA-105 handleiding

128 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 78 van 128
Enter Setup
Exit Setup
- 87 -
The barcode length is composed of "minimum length" and "maximum length". If the
maximum length is less than the minimum length, the barcode only recognizes the
two lengths of Scan. If the maximum length is equal to the minimum length, only
barcode of this length is supported.
STANDARD 25 Maximum
decoding length
$>: R000D21.<$
STANDARD 25 Minimum
decoding length
$>: R000D31.<$
Example: Limit the scanner to only read barcodes with a minimum of 8 bytes and a
maximum of 12 bytes
1) Scan code "Enter setup"
2) Scan code “STANDARD 25 Minimum decoding length”
3) Scan Data code “8” (in Appendix)
4) Scan code "Save" (in Appendix)
5) Scan code “STANDARD 25 Maximum decoding length”
6) Scan Data code “C” (in Appendix)
7) Scan code "Save" (in Appendix)
8) Scan code "Exit setup"
6.14 Data Logic 25
6.14.1 Enable/Disable scan
Enable
$>:S01019F.<$
Disable (Default)
$>:S01009F.<$