● LS200-PM25: IP30 LoRaWAN PM2.5 Sensor
Default setting:
Max Time: 8400 s
Min Time: 30 s (US915, AU915, KR920, AS923, IN865)
120 s (EU868)
Report Type count = 1
1. Max Time and Min Time rules, configured by formula: Max Time ≥
Report Type count * Report Min Time+10
2. Min Time configuration is invalid. But due to software limitations, it is
required to comply with the above formula and not equal to 0.
3. The Min Time setting of EU868 cannot be less than 120 s, and the
Max Time cannot be less than 370 s.
● LS250-PLUG: IP20 LoRaWAN Power Plug with Power Meter
Default Setting:
Max Time: 900 s (15 min)
Min Time: 2 s
Current Change: 100 mA (0x0064)
Power Change: 20 W (0x14)
1. The device initially reports the ON/OFF status, energy consump-
tion, and over-current alarm. After a 10-second interval, it transmits
voltage, current, and power data.
2. When an over-current alarm is triggered, the device automati-
cally disconnects the load, and the network indicator flashes rapidly
approximately 25 times.
3. If the detected current exceeds the rated load current limit for more
than 2 seconds, the device will automatically disconnect the load to
prevent damage.