● LS200-VOC: IP65 LoRaWAN TVOC Sensor
LS200-VOC measurement range is 0 ppb to 60000ppb.
Default Settings
Max Time: 900 s
Min Time: 900 s
1. The Min Time should not be less than 4 minutes.
2. The Max Time should be greater than or equal to the Min Time.
Battery Change: 0.1 V (0x01)
TVOC Change: 300 ppb (0x012C)
Excellent 0 to 65 ppb
Good 65 to 220 ppb
Moderate 220 to 660 ppb
Poor 660 to 2200 ppb
Unhealthy 2200 to 60000 ppb
Note: This rangerepresentscommonreferencevalues; the exact standards should
be based on local regulations.
1. LS200-VOC requires a 13-hour initialization period after the first
power-on. During this time, the sensor undergoes automatic calibra-
tion, and the data readings may be biased. Accurate measurements
will be available after the calibration process is complete.
2. Once the sensor is operating normally, valid data readings can be
obtained 20 minutes after the device is restarted. This 20-minute
period allows the sensor to reach a stable state.
3. If the sensor is damaged, fails to initialize, or encounters three
consecutive data reading failures after warming up, the device will
report a value of 0xFFFF. This process is automatically managed by
the device upon startup, and no user intervention is required.