Attempting To Service This Product. All Safety Precautions Must Be Followed.
●
WARNING – Risk of Fire due to Flammable Refrigerant Used. Follow Handling Instructions Carefully in
Compliance with National Regulations.
Installation Safety Precaution
1) Select the installation location according to the requirement of this manual. (See the requirements in installation
part).
2) Handle unit transportation with care, the unit should not be carried by only one person if it is more than 20kg.
3) When installing the indoor unit and outdoor unit, a sufficient fixing bolt must be installed, make sure the
installation supporter is firm.
4) Ware safety belt if the height of working is above 2m.
5) Use equipped components or appointed components during installation.
6) Make sure no foreign objects are left in the unit after finishing installation.
Improper installation may lead to fire hazard, explosion, electric shock or
injury.
Safety precautions for Installing and Relocating the unit.
To ensure safety, please be mindful of the following precautions.
Warnings
1) When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other
than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or
compressor rupture, resulting in injury.
2) When installing or moving this unit, do not charge the refrigerant which is not comply with that on the
nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.
3) When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running
in cooling mode. Then, fully close the valve at high pressure side (two-way valve). About 30-40 seconds later, fully
close the valve at low pressure side (3-way valve), immediately stop the unit and disconnect power. Please note
that the time for refrigerant recover should not exceed 1 minute.
If refrigerant recovery takes too much time, may be cause compressor overheat, resulting in injury.
4) During refrigerant recovery, make sure that two-way valve and 3-way valve are fully closed and power is
disconnected before detaching the connecting pipe.