Pioneer WYT009ALSI24RL handleiding

79 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 24 van 79
24
PART Installation and Maintenance
1. Notes for installation and maintenance
Safety Precautions
Important!
Please read the safety of precautions carefully before installation and maintenance. The following contents are very
important for installation and maintenance. Please follow the instructions bellow.
The installation or maintenance must accord with the instructions.
Comply with all national electrical codes and local electrical codes.
Pay attention to the warnings and cautions in this manual.
All installation and maintenance shall be performed by distributor or qualified person.
All electric work must be performed by licensed technician according to local regulations and instructions given in
this manual.
Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty
and other accidents.
Please use the flammable gas detector to check before unload and open the container.
No fire source and smoking.
According to the local rules and laws.
Warnings
Electrical safety Precautions.
1) Cut off the power supply of air conditioner before checking and maintenance.
2) The air conditioner must apply specialized circuit and prohibit share the same circuit with other appliances.
3) The air conditioner should be installed in suitable location and ensure the power plug is touchable.
4) Make sure each wiring terminal is connected firmly during installation and maintenance.
5) Have the unit adequately grounded. The grounding wire can’t be used for other purposes.
6) Must apply protective accessories such as protective boards, cable-cross loop and wire clip.
7) The live wire, neutral wire and grounding wire of power supply must be corresponding to the live wire, neutral
wire and grounding wire of the air conditioner.
8) The power cord and power connection wires can’t be pressed by hard objects.
9) If power cord or connection wire is broken, it must be replaced by qualified person.
10) If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire
from the manufacture or distributor. Prohibit prolong the wire by yourself.
11) For the air conditioner without plug, an air switch must be installed in the circuit. The air switch should be all-pole
parting and the contact parting distance should be more then 3mm.
12) Make sure all wires and pipes are connected properly and the valves are opened before energizing.
13) Check if there is electric leakage on the unit body. If yes, please eliminate the electric leakage.
14) Replace the fuse with a new one of the same specification if it is burnt down, don’t replace it with a cooper wire or
conducting wire.
15) If the unit is to be installed in a humid place, the circuit breaker must be installed.
Risk of fire safety Precautions.
WARNING Risk Of Fire. Flammable Refrigerant Used. To Be Repaired Only By Trained Service Personnel. Do
Not Puncture Refrigerant Tubing.
WARNING Risk Of Fire. Dispose Of Properly In Accordance With Federal Or Local Regulations. Flammable
Refrigerant Used.
WARNING Risk Of Fire. Flammable Refrigerant Used. Consult Repair Manual/Owner’s Guide Before

Bekijk gratis de handleiding van Pioneer WYT009ALSI24RL, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPioneer
ModelWYT009ALSI24RL
CategorieNiet gecategoriseerd
TaalNederlands
Grootte16884 MB