For your safety
8220_en_06 PHOENIX CONTACT 19
1.11 Abbreviations used
1.12 Safety hotline
Should you have any technical questions, please contact our 24-hour hotline.
Abbreviation Meaning Standard Example
SIL Safety integrity level EN 61508 SIL 2, SIL 3
SIL CL SIL claim limit EN 62061 SIL CL 3
Cat. Category EN ISO 13849 Cat. 2, Cat. 4
PL Performance level EN ISO 13849 PL e, PL d
Abbreviation Meaning
SPNS Safe PROFINET controller
PELV Protective extra-low voltage
A circuit in which the voltage cannot exceed 30 V AC, 42.4 V peak value
or 60 V DC under normal conditions, and under single-fault conditions,
except in the event of grounding errors in other circuits.
A PELV circuit is like a SELV circuit, but is connected to protective earth
ground.
(According to EN 61131-2)
For terms and abbreviations used for PROFIsafe, please refer to “Appendix: Terms for
PROFIsafe” on page 69.