Phoenix Contact CHARX PS/3AC/920DC/87.5KW handleiding

96 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 34 van 96
CHARX PS...87.5KW
34 / 94
PHOENIX CONTACT 109484_en_01
3.7.2 Remote OFF
NOTE: After remote OFF voltage may still be present in the system.
Please refer to “Disconnecting the system” on page 66.
Remote OFF is used to switch off charging. The inputs of bus distributor card A20 are con-
nected to terminal X12 for the customer:
In the DC power module, the signals are cleared internally and read in via an optocoupler
level. In the DSP, the read signal immediately leads to blocking of the respective DC power
module/charging point.
Charging point 1 (rack 1, 2): Terminal X12.1/2
Charging point 2 (rack 3, 4): Terminal X12.4/5