Perfect Aire 2PHG5000 handleiding

12 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 8 van 12
8
INSTALLATION INSTRUCTIONS
(Continued)
Figure 6
If Heater is to be
turned and wire
is inside conduit.
If Heater is to
be connected
with NM Cable.
If Heater is to be
connected with
Flexible Conduit.
CONDUIT CONDUIT CONNECTOR
FLEXIBLE CONDUIT
FLEXIBLE
CONDUIT CONNECTOR
3 FT. MIN.
FLEXIBLE
NIM CABLE
FLEXIBLE NIM CABLE
CONNECTOR
(use per electrical codes)
FLEXIBLE CONDUIT CONNECTOR
(use per electrical codes)
1 2
7
12
3 4
3. Pull enough wire into the heater and connect
to wire to the Power Block located in the
electrical area of the heater, See Figure 7.
4. Be sure to torque all terminal screws and power
block lugs tight, see SPECIFICATIONS and
NEC/local codes, for required torque values,
failure to do so can overheat the power blocks.
5. Turn on power at the main circuit breaker panel.
Notice the YELLOW Power Indicator Light on
the Control Panel will glow.
WARNING: It is advised that at the start of each
heater season, the power should be turned o
at the circuit breaker and the LI & L2 lug screws
checked for tightness and proper torque.
The heater should be cleaned and checked
for mechanical and electrical integrity. See
SPECIFICATIONS and NEC/local codes.
ADJUSTING AIR FLOW
1. Swivel the unit–If mounted on a single center
lag bolt Figure 4a, turn the entire heater and
bracket assembly left or right.
2. Tilt the unit–Loosen the top Small Knob-
Screws and thread into provided holes in
heater until tight. See Figure 5.
3. Adjust the louvers in front of the heater as
desired. See Figure 5.
Figure 7
L2
HOT
L1
HOT
GROUND
(or bare copper)
NOTE: DO NO OPERATE THE HEATER WITH
THE FRONT LOUVERS CLOSED, DAMAGE TO
THE HEATER COULD RESULT.
CONNECTING THE POWER
1. With the power o at the breaker, remove all
screws from the bottom lid for access to the
electrical section of the heater.
2. Attach exible cable through a knock-out in
the side of the heater following NEC and local
codes, See Figure 6 and SPECIFICATIONS for
recommended wiring and circuit breakers.
NOTE: For certain applications, conduit
may be required (See Figure 6). Check local
electrical codes. If you run the wiring in conduit
and wish to be able to turn the heater, be sure
to purchase enough exible conduit to allow
the heater to be turned.

Bekijk gratis de handleiding van Perfect Aire 2PHG5000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPerfect Aire
Model2PHG5000
CategorieHeater
TaalNederlands
Grootte1753 MB