PCE Instruments PCE-SCI-L handleiding

24 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 24
7
PCE Instruments | www.pce-instruments.com
9.  Connections and dimensions (mm (inch))
Table 10 | INPUT signal connections
INPUT
signal
Input terminals Section
...
1 2 3 4 5 6
load cell Vexc - sense - signal - Vexc + sense + signal +
10.1
millivolts mV - mV +
10.2
Table 11 | OUTPUT signal connections
OUTPUT
signal
Output terminals Connections
7 8 9
4/20 mA
active output
mA-
(in)
mA+
(out)
789
mA+
mA-
4/20 mA
passive output
*
(
*
external loop
power needed)
mA+
(out)
mA-
(in)
789
mA+
mA-
0/10 Vdc
common
+Vdc
789
common
+Vdc
fuse
signal -
sense -
Vexc -
POWER (ABC)
18 to 265 Vac/dc isolated
OUTPUT SIGNAL (789)
sense +
common (0 Vdc or passive mA current out)
signal 4/20 mA (mA current in)
signal 0/10 Vdc (or active mA current out)
Standard (35 mm) DIN
rail mount
1 2 3
106 mm
(4.17’’)
108mm
(4.25’’)
INPUT SIGNAL (123 456)
~ +
~ -
A B C
4 5 6
7 8 9
22.5 mm
(0.89’’)
Vexc +
signal +
see
‘Table 10’
see ‘Table 11’
Fuse - This instrument does not
include internal protection fuse.
According to security regulation
EN 61010-1, add a protection fuse to
the power line to act as a disconnection
element, easily accessible to the operator
and identied as a protection device. Use
time-lag fuse, with value :
• 250 mA for voltages > 50 Vac/dc
• 400 mA for voltages < 50 Vac/dc
SIGNAL CONVERTER
PCE-SCI series

Bekijk gratis de handleiding van PCE Instruments PCE-SCI-L, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPCE Instruments
ModelPCE-SCI-L
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4371 MB