¾ Do not operate the product if the power
cord or power plug are damaged, nor if the
product does not work or is damaged in any
way.
¾ If the power cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
¾ Do not disconnect the power plug from the
socket outlet by pulling on the power cord.
Special safety information for rope
hoists
¾ Persons who intend to use the product
must first receive appropriate training or
instructions.
¾ It is prohibited to move persons with the
product.
¾ It is prohibited to lift loads in excess of the
nominal load.
¾ Do not attempt to lift stuck or jammed loads.
¾ The steel cable must be taut when lifting the
load.
¾ Do not pull the loads in horizontal direction.
¾ Avoid switching the product on and off
rapidly (inching operation).
¾ Always be attentive when operating the
product.
¾ Do not leave hanging loads unattended
without taking appropriate safety measures.
¾ Do not stand or work underneath raised
loads.
¾ The product has not been outfitted with a
rated power limit. Do not attempt to lift the
load further when the overheat protection
limits operation. In this case, the load has
exceeded the product’s nominal power.
¾ Do not use the maximum/minimum length
levers
15
16
routinely as a stop mechanism.
These levers serve as a stop mechanism only
in emergencies.
¾ Before you begin: Check whether
– the steel cable
14
is wound properly
around the drum
17
and whether
– the space between coils is less than the
diameter of the cable itself (Fig. D).
Assembly
(Fig. E)
m
DANGER!
u The square tube must be able to bear
a minimum load of 500 kg at the
points where the product is fastened. If
you are unsure, consult a professional
(e.g. a structural engineer).
u Seek advice from a qualified technician to
ensure all screws are tightened fully and
correctly.
u A qualified technician or a properly
trained person should check the anchoring
of the square tube before the product is
started.
¾ Fasten the product with the mounting
brackets
1
and the mounting screws
2
to
a suitable square tube.
¾ Tighten the mounting screws
2
.
Before first use
¾ Remove the transport lock from the steel
cable
14
. Cut the rubber band and remove
it.