Parkside PRM 1800 C3 handleiding
Handleiding
Je bekijkt pagina 20 van 49

□ Check all connections (handlebars, cuttings collec
tion bag
7
, etc.) for tight fit.
● Maintenance
As a rule, the device does not require maintenance
except for the measures described in the section entitled
"Cleaning and inspection after each use". There is no
need to lubricate or readjust any parts.
Additionally check once a year:
- Wheels
12
move easily.
-
Functionality and ease of movement of the cutting
height adjustment
13
.
- Functionality and ease of movement of the
discharge flap
8
.
- Damage to the device (e.g. fractured housing parts
or worn cuttings collection bag
7
.
Contact customer service or a specialist workshop if you
find any defects. Do not operate the device once you
have found any defects.
● Transport
-
Always transport the device with the handlebars
folded in (see Fig. G).
- Exclusively lift the device on the carry handle
15
.
- Exclusively transport the device in normal position;
prevent tilting while transporting.
- When transporting the device in vehicles, the
device must be secured in accordance with the
applicable regulations (load securing).
●
Troubleshooting
Problem Potential
cause
Remedy
Motor does not
start.
Power cable has
not been
connected prop
erly.
Check the power
cable has been
positioned
correctly.
Socket not ener
gised/fuse or
circuit breaker has
tripped.
Check the power
cable for damage.
You have not
pressed the Start
button
1
and
the safety switch
3
.
Proceed as
described in the
section entitled
"Switching the
motor on and off".
Motor overload
protection has trig
gered, motor is
overheated.
Let the device cool
down for 15-20
minutes.
Device not running
smoothly
Device emitting
unusual noise
Lack of output
The selected
cutting height is
too low.
Adjust the cutting
height 2 levels
higher.
The cuttings collec
tion bag
7
is
overfilled or the
discharge chute is
blocked.
Empty the cuttings
collection bag
7
and remove
cuttings from the
discharge chute.
Blades blocked by
foreign objects.
Check the blades
compartment for
foreign objects
and remove any
foreign objects.
Blades blunt or
defective.
Check the blades
and have them
sharpened or
replaced at a
specialist work
shop, if necessary.
20 GB/IE/NI
Cleaning / Maintenance / Transport / Troubleshooting
Bekijk gratis de handleiding van Parkside PRM 1800 C3, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Parkside |
| Model | PRM 1800 C3 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 4989 MB |