Burn smaller larger
Weld seam width larger smaller
Weld bead flatter higher
Weld seam fault larger smaller
NOTE: You decide for yourself which type of welding is most suitable, once you have welded a
sample piece.
NOTE: Once it has worn down completely, the electrode must be replaced.
z Maintenance and cleaning
NOTE: The welding device must be regularly serviced and overhauled for proper function and
for compliance with the safety requirements. Improper and wrong operation may cause failures and
damage to the device.
Before performing cleaning work on the welding tool, disconnect the mains cable
10
from the power
outlet to ensure the tool is safely isolated from the power supply.
Clean the exterior of the welder and its accessories regularly. Use compressed air, cotton waste or a
brush to remove dirt and dust.
NOTE: The following kinds of maintenance work must be performed only by suitably-qualified
personnel.
The current regulator, earthing device and internal cables must be serviced regularly.
Check the insulation resistance levels of the welder regularly. To do this use an appropriate
measuring device.
In case of a defect or a necessary replacement of equipment parts, please contact the appropriate
qualified personnel.