SYSTEM CABLE REMOVAL (BATTERY POWERED INDICATOR MODULE)
1. Grip the retention spring on both
sides.
2. Pull down on the retention spring
approximately 1/16 inch [1.5 mm].
3. Continue holding the retention
spring down while pulling back on
the right-angle connector to release
the system cable.
O-RING AND GASKET REPLACEMENT
The o-rings and gaskets can be replaced if they become dry or brittle. In critical sealing applications, such as wash down envi-
ronments, it is recommended that the o-rings and gaskets be replaced every 5 years.
BATTERY FREE INDICATOR MODULE
For the battery free indicator module, order Panduit SKU
VS2-AVT-GASKET for gasket replacement kit.
1. Unplug the system cable and remove the panel nut.
2. Squeeze the top and bottom of the housing and pull
back to release the latches from the faceplate.
3. Separate housing from faceplate and replace gasket.
Indicator
Module
Faceplat
e
Instruction Label
Indicator
Module
Housing
Panel
Nut
Gasket
BATTERY POWERED INDICATOR MODULE
For the battery powered indicator module, order Panduit SKU
VS-AVT-ROR for o-rings and gasket replacement kit.
1. Unplug the system cable and remove the panel nut.
2. Replace the gasket and o-rings.
3. Apply a light coating of silicone grease to the o-rings to pro-
mote sealing and extend o-ring life.