36
Menus
For installer
Menu Default Setting Setting Options / Display
Yes Smart After selecting for the external pump Schedule Season
setting
Season 1 : Dec (Refers to Winter
season)
Season 2 : Mar (Refers to Spring
season)
Season 3 : Jun (Refers to Summer
season)
Season 4 : Oct (Refers to Autumn season)
- There are total 4 seasons to be set
- Set the starting month for each
season.
(Eg. when Season 1 is set to Dec and
Season 2 is set to Mar, month of December
to February will be treated as Season 1).
Schedule
Select Confirm
10:34am,Mon
Schedule setting
Bivalent connection
Season setting
Bivalent connection
Season 1: Start month
Range: (Jan~Dec)
Steps: ±1month
Select Confirm
10:34am,Mon
Dec
Yes Smart After selecting for the external pump Schedule Schedule
setting
Start time (Pattern 1) : 3:00am
Start time (Pattern 2) : 9:00am
Start time (Pattern 3) : 4:00pm
Start time (Pattern 4) : 9:00pm
- For each season, there are total 4 patterns
can be set.
Schedule setting
Select Confirm
10:34am,Mon
Season 3
Season 2
Bivalent connection
Season 1
Price (Pattern 1/2/3/4) : 1
- Set the target start time and the appropriate
electricity price for each pattern.
Select Edit
10:34am,Mon
3.
2.
Season 1
1.
Start time
4:00pm
9:00am
3:00am
Price( /kWh)
0.0
0.0
0.0
- Select “1” to edit both start time and
electricity price. Select “2” to edit electricity
price only.
Schedule setting
Select Confirm
10:34am,Mon
Season 3
Season 2
Bivalent connection
Season 1
Select
1: To edit time & price
2: To edit price only
2
1