Panasonic DP-001-P handleiding

12 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 6 van 12
6
DP-0
ORDER GUIDE
Model No.
DP-001
Rated pressure range
1 : −100.0 to +100.0 kPa (Low pressure type)
2 : 0.000 to +1.000 MPa (High pressure type)
-P-J
Cable
None : Connector attached cable 2 m 6.562 ft
J : Type without connector attached cable
Comparative output
None : NPN output type
P
: PNP output type
Type Appearance Rated pressure range Model No. Pressure port Comparative output
Low pressure
type
*CN-14A-C2
(Connector attached cable
2 m 6.562 ft ) is attached.
−100.0 to +100.0 kPa
DP-001
M5 female thread
NPN open-collector transistor
DP-001-P
PNP open-collector transistor
High pressure
type
0.000 to +1.000 MPa
DP-002
NPN open-collector transistor
DP-002-P
PNP open-collector transistor
Type without connector attached cable Accessory
Type without connector attached cable CN-14A-C2 is available. When ordering
this type, sufx “-J” to the end of Model No.
(e.g.) Type without connector attached cable of DP-001-P is “DP-001-P-J
CN-14A-C2 (Connector attached cable 2 m 6.562 ft)
Designation Model No. Description
Connector
attached cable
CN-14A-C1
Length: 1 m 3.281 ft
0.2 mm
2
4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
CN-14A-C2 (Note)
Length: 2 m 6.562 ft
CN-14A-C3
Length: 3 m 9.843 ft
CN-14A-C5
Length: 5 m 16.404 ft
Connector
attached cable
(Flexible cable)
CN-14A-R-C1
Length: 1 m 3.281 ft
0.2 mm
2
4-core exible cabtyre
cable with connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
CN-14A-R-C2
Length: 2 m 6.562 ft
CN-14A-R-C3
Length: 3 m 9.843 ft
CN-14A-R-C5
Length: 5 m 16.404 ft
Connector
CN-14A
Set of 10 housings and 40 contacts
Sensor mounting
bracket
MS-DP1-1
Allows sensors to be installed on the ooring or ceiling.
Multiple sensors can also be mounted closely.
MS-DP1-5
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
Panel mounting
bracket
MS-DP1-8
Allows installation to panels with thickness of 1 to 3 mm 0.039
to 0.118 in. Multiple sensors can also be mounted closely.
Front protection
cover
MS-DP1-3
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
OPTIONS
Note: The connector attached cable CN-14A-C2 is supplied with the DP-0 series.
Recommended connector
Contact: SPHD-001T-P0.5,
Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details
of the recommended products.
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details
of the recommended products.

Bekijk gratis de handleiding van Panasonic DP-001-P, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPanasonic
ModelDP-001-P
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6757 MB