09User Manual
Electrical Connection Safety
The appliance is fitted with an approved 15 Amp flexible
cord and plug which must be connected to a correctly
earthed socket outlet.
The manufacturer is not liable for any direct or indirect
damage caused by faulty installation or connection. It is
therefore necessary that all installation and connection
operations are carried out by qualified personnel
complying with the local and general regulations in force.
The wire section on the cable must not be less than1.5mm
(3 × 1.5 cable). Use only the special cables available at our
service centres
Connection of the Feeding Cable to the Mains
Connect the feeding cable to a plug suitable for the load
indicated on the rating plate of the product. In case of a direct
connection to the mains (cable without plug), it is necessary
to insert a suitable omnipolar switch before the appliance,
with minimum opening between contacts of 3 mm (the
grounding wire should not be interrupted by the switch).
Before connecting to the mains, make sure that:
The electrical counter, the safety valve, the feeding line and
the socket are adequate to withstand the maximum load
required(see rating plate).
The supply system is regularly grounded, according to the
regulations in force.
The socket or the omnipolar switch can easily be reached
after the installation of the oven.
After carrying out the connection to the mains, check that
the supplying cable does not come into contact with parts
subject to heating.
Never use reductions, shunts, adaptors which can cause
overheating or burning.
Installation Instructions (Continued)
The manufacturer is not liable for any direct or indirect
damage caused by faulty installation or connection. It is
therefore necessary that all installation and connection
operations are carried out by qualified personnel complying
with the local and general regulations in force.
Electrical features
Oven light 2×25W
Upper heating element 900W
Bottom heating element 1800W
Grill heating element 2300W
Circular heating element 2×1250W
This appliance shall be installed only by authorised
persons and in accordance with the manufacturer's
installation instructions, local gas fitting regulations,
municipal building codes, electrical wiring regulations,
local water supply regulations.
Ventilation
In general, the appliance should have adequate ventilation for
complete combustion of gas, proper flueing and to maintain
temperature of immediate surroundings within safe limits.
Combustible Surfaces
Any adjoining wall surface situated within 200mm from the
edge of any hob burner must be a suitable noncombustible
material for a height of 150mm for the entire length of the
hob. Any combustible construction above the hotplate
must be at least 600mm above the top of the burner and
no construction shall be within 450mm above the top of the
burner. Zero clearance is permitted on side and rear adjoining
surfaces below the hob.
Earth
Neutral
Live
5
4
3
2
1
12 34 5
L1 N
PE
220-240V
L2 L3
L1: min.2.5mm2
N: min.2.5mm2
PE: min.1.5mm2
L2: min.1.5mm2
L3: min.1.5mm2
PE