10User Manual OFOGC9010X
Installing Your Freestanding Cooker (Continued)
Prior to Beginning Installation
Ensure that the local distribution conditions (nature of the gas
and gas pressure) and the adjustment of the appliance are
compatible;
The adjustment conditions for this appliance are stated on
rating plate.
This appliance is not connected to a combustion products
evacuation device. It shall be installed and connected in
accordance with current installation regulations. Particular
attention shall be given to the relevant requirements regarding
ventilation.
Electrical Connection Safety
The appliance is fitted with an approved 15 Amp flexible cord
and plug which must be connected to a correctly earthed socket
outlet.
The manufacturer is not liable for any direct or indirect damage
caused by faulty installation or connection. It is therefore
necessary that all installation and connection operations are
carried out by qualified personnel complying with the local and
general regulations in force.
The wire section on the cable must not be less than1.5mm
(3 × 1.5 cable). Use only the special cables available at our
service centres
Freestanding Oven Clearances
A
Minimum vertical distance between benchtop
and cabinet extending above the counter
450 mm
B
Minimum clearance from left and right-hand
edge of the freestanding oven to the nearest
combustible surface*
200 mm
C
Minimum clearance from the top of the burner
cap (cooking surface) to:
Overhead cabinet centred above the cooktop
(combustible/unprotected)*
Overhead cabinet centred above the cooktop
(non-combustible/protected)*
Ventilation rangehood centred above
the cooking surface
650 mm
450 mm
750 mm
D
Width of cabinetry opening 900 mm
E
Maximum height of cabinetry immediately
adjacent to the freestanding oven (from floor
to countertop)
920 mm
F
Maximum depth from wall to cabinetry face 600 mm
* NOTE: Installation clearances and protection of combustible
surfaces shall comply with current local regulations, such as
AS/NZS5601.1 (latest edition) Gas Installations code. These
standards specify that where required, protection shall ensure
that the surface temperature of the combustible surface does
not exceed 65°C above room temperature.
NOTE: Depending on the height of the feet adjustment,
the cooking surface must sit flush or above countertop level.
L
N
A
E
D
C
BB

Bekijk gratis de handleiding van Omega OFOGC9010X, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkOmega
ModelOFOGC9010X
CategorieFornuis
TaalNederlands
Grootte4205 MB