25 OCI603KZCOMUser Manual
C1
High temperature of ceramic plate
sensor.
Wait for the temperature of ceramic plate
return to normal.
Touch “ON/OFF” button to restart unit.
E3
Temperature sensor of the IGBT failure
-open circuit.
Replace the power board
E4
Temperature sensor of the IGBT failure
-short circuit.
C2 High temperature of IGBT.
Wait for the temperature of IGBT return
to normal.
Touch “ON/OFF” button to restart unit.
Check whether the fan runs smoothly;
if not , replace the fan.
EL Supply voltage is below the rated voltage.
Please inspect whether power supply
is normal.
Power on after the power supply
is normal.
EH Supply voltage is above the rated voltage.
EU Communication error.
Reinsert the connection between the
display board and the power board.
Replace the power board or the display
board.
Troubleshooting
Failure Display and Inspection