Nord Modular G2 handleiding
Handleiding
Je bekijkt pagina 86 van 291

6. Working in the Editor: Modulation NORD MODULAR G2 V1.4x
Page 86
E
XAMPLE
OF
A
P
ATCH
THAT
USES
BOTH
THE
P
OLY
AND
FX A
REAS
This example shows a Patch where both the Poly and FX
Areas are used:
The ‘2-Out1’ module in the Voice Area is set to route the
signal to FX In 1/2, the Left and Right output of the ‘FX
In1’ module in the FX Area. The sum of all voices from
the Voice Area is sent to the FX Area to be processed in
the ‘Reverb1’ module and output at O
UT
1 and O
UT
2
jack of the synthesizer.
D
OWNLOAD
A
P
ATCH
TO
THE
SYNTHESIZER
If you have opened a couple of Patches in the Editor while the synth wasn’t connected and you want to
download one of the Patches from the Editor to the synth, do either of the following:
1. Right-click on the Patch window background and select a Slot from the bottom of the popup. This
will download your Editor Patch, overwriting the Patch that is currently in the destination Slot.
OR:
2. Select Patch|Download To Slot and select Slot in the dialog box that appears.
S
TORE
A
P
ATCH
A Patch can be stored in two different locations: in the internal memory of the synthesizer, and/or on
disk on the computer. The examples below describes three different ways of saving/storing a Patch.
1. Save a Patch only on the computer by selecting File|Save. File|Save As will let you rename and/or
relocate the Patch before saving to disk. File|Save All will save all open Editor Patches to their orig
-
inal locations.
2. Store a Patch in one of the Nord Modular G2 internal memory locations by pressing the S
TORE
but-
ton on the front panel once. The
LED
above the S
TORE
button will flash. Select a bank (1-32) with
the U
P
/D
OWN
N
AVIGATOR
buttons and a memory location (1-128) with the R
OTARY
D
IAL
. Con-
firm by pressing S
TORE
again. Abort by pressing any other button.
3. To store a Patch in the Nord Modular G2 internal memory from the Editor, select Synth|Save In
Synth. Select a memory location and a bank from the Drop-down lists and click ‘Save’. Note that
the original Patch in the selected memory location (if any) will be overwritten by your new
Patch. Make sure you do not overwrite Patches you want to keep!
There is a memory protect function to minimize the risk of accidentally overwriting Patches. Read more
about the internal memory protection in the section “Memory Prot |Sy” on page 32.
Bekijk gratis de handleiding van Nord Modular G2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Nord |
| Model | Modular G2 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 60689 MB |







