Nord Modular G2 handleiding

291 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 77 van 291
NORD MODULAR G2 V1.4x 5. The Editor application: Modulation
Page 77
M
OD
-
AMOUNT
KNOBS
(
ATTENUATORS
)
There are three different response
behaviors for the mod-amount knobs
next to the modulation inputs: linear
[Type I], exponential/dB [Type II] and
amplified linear [Type III]. The different
response type(s) will be indicated for
each module in the module reference
section starting on page 155.
[T
YPE
I]
The mod-amount knobs attenuates the
incoming signal in a linear fashion. A
setting of 100 (maximum) leaves the
incoming signal unaffected, a setting of
50 attenuates the incoming signal by a
factor 0.5 (leaving half of the level of the
incoming signal to modulate). A setting
of 0 shuts off the modulation completely.
Oscillator pulse width modulation is an
example of Type I attenuation. When
mod-amount knobs have a value display
consider the displayed value as a
percentage.
[T
YPE
II]
The mod-amount knob attenuates the incoming signal in an exponential fashion. A setting of 100
(maximum) leaves the incoming signal unaffected, a setting of 50 attenuates the incoming signal by a
factor considerably less than 0.5 (leaving less than half of the level of the incoming signal to modulate).
A setting of 0 shuts off the modulation completely. The pitch mod-input on the various oscillators and
the ‘dB’ attenuation alternative in the Mixer modules are examples of Type II attenuation. Note that Exp
and dB are in fact exactly the same scale, but display differently if the mod-amount knob has a value
display.
[T
YPE
III]
The mod-amount knob affects the incoming signal in an attenuated and amplified, linear fashion. A
setting of 200% (knob position 127 or maximum) amplifies the incoming signal to twice its original level,
a setting of 100% (knob position 64) leaves the incoming signal unaffected and a setting of 50% (Knob
position 32) attenuates the incoming signal by a factor of 0.5 (leaving half of the level of the incoming
signal to modulate). A setting of 0 shuts off the modulation completely. The frequency mod-input on the
various filters are the sole examples of Type III attenuation.
K
NOB
POSITIONS
To be compatible with the
MIDI
standard all knobs have 128 physical knob positions. When a knob is
tweaked in the Editor a temporary yellow popup will display the knob value plus the actual knob position
in parenthesis. The knob position numbers in parenthesis are also the numbers send by
MIDI
to and from
other
MIDI
devices. After recording a knob movement through a
MIDI
CC
# in a
MIDI
-sequencer program
on a computer the sequencer data will show the knob positions, and not the values displayed at the top of the
Mod-amount setting
Signal attenuation/
amplification factor
TYPE I
TYPE II
TYPE III

Bekijk gratis de handleiding van Nord Modular G2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkNord
ModelModular G2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte60689 MB