MSW -CONCRETE-VPO750 handleiding
Handleiding
Je bekijkt pagina 26 van 264

EN
ARBOR HOLE OUT
OF ROUND
• Collars / flanges are not
properly tightened,
permitting blade to rotate or
vibrate on the shaft
• Collars / flanges are worn or
dirty.
• Blade is not properly
mounted
• Make certain the blade is mounted on
the proper shaft diameter. Tighter the
shaft nut with a wrench to make
certain that the blade is secure
• Clean collars / flanges, make sure they
are not worn, Tighten arbor nut
• Make sure the pin bole slides over
drive pin
BLADE WORN OUT
OF ROUND
• Shaft bearing is worn
• Surges occur because engine
is not properly tuned
• Blade arbor hole is damaged
from incorrectly mounting the
blade
• Bond / matrix is too hard for
material
• Blade is slipping, wearing one
half of blade more than other.
• Check for bad bearings, bent
shaft, or worn mounting
arbor
• Install new blade shaft bearing or blade
shaft, as required
• Tune engine according to
manufacturer’s manual
• If core is worn or arbor hole damaged,
DO NOT USE, Contact blade
manufacturer
• Replace worn shaft or mounting arbor
bushing
• Make certain that drive pin is
functioning
• Tighten spindle nut
V. LUBRICATION AND SERVICE
• Check oil levels, wiring, hoses (air, fuel, water) and lubricate machine daily.
• Repair or replace all worn or damaged components immediately.
• Check drive belt tension, do not over-tension.
• Make sure machine has full set of matched belts.
• Check blade shaft, make sure arbor and threads are not worn, damaged, or bent.
• Blade shaft bearings should be tight, no free play side-to-side or up and down.
• Grease blade shaft bearings daily.
• Blade collars should be clean, free of nicks and burrs. No diameter wear and not out of
round.
• Drive pin not excessively worn or bent and free of gouges.
• All guards in place and secure.
• All fasteners tight and secure.
• Air filter / oil filter (hydraulic or engine) clean.
• Flush clean water through the pump and spray the assembly every night. This prolongs the
pump and blade life.
• Clean machine before starting lubrication maintenance.
• Ensure machine is on solid, level ground before starting maintenance.
• During lubrication maintenance ensure strict cleanliness is observed at all times.
• To avoid the risk of accidents, use the correct tool for the job and keep tools clean.
• The draining of engine oil is best carried out when the oil is warm NOT hot.
• Any spilled oil must be cleaned up immediately.
• Use only clean containers for oil and only CLEAN, FRESH oils and grease of correct grade.
• Contaminated Water / Fluids / Oil / Filters Must Be Disposed of Safely.
Bekijk gratis de handleiding van MSW -CONCRETE-VPO750, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | MSW |
| Model | -CONCRETE-VPO750 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 46743 MB |