ARBOR HOLE OUT
OF ROUND
Collars / flanges are not
properly tightened,
permitting blade to rotate or
vibrate on the shaft
Collars / flanges are worn or
dirty.
Blade is not properly
mounted
Make certain the blade is mounted on
the proper shaft diameter. Tighter the
shaft nut with a wrench to make
certain that the blade is secure
Clean collars / flanges, make sure they
are not worn, Tighten arbor nut
Make sure the pin bole slides over
drive pin
BLADE WORN OUT
OF ROUND
Shaft bearing is worn
Surges occur because engine
is not properly tuned
Blade arbor hole is damaged
from incorrectly mounting the
blade
Bond / matrix is too hard for
material
Blade is slipping, wearing one
half of blade more than other.
Check for bad bearings, bent
shaft, or worn mounting
arbor
Install new blade shaft bearing or blade
shaft, as required
Tune engine according to
manufacturer’s manual
If core is worn or arbor hole damaged,
DO NOT USE, Contact blade
manufacturer
Replace worn shaft or mounting arbor
bushing
Make certain that drive pin is
functioning
Tighten spindle nut
V. LUBRICATION AND SERVICE
Check oil levels, wiring, hoses (air, fuel, water) and lubricate machine daily.
Repair or replace all worn or damaged components immediately.
Check drive belt tension, do not over-tension.
Make sure machine has full set of matched belts.
Check blade shaft, make sure arbor and threads are not worn, damaged, or bent.
Blade shaft bearings should be tight, no free play side-to-side or up and down.
Grease blade shaft bearings daily.
Blade collars should be clean, free of nicks and burrs. No diameter wear and not out of
round.
Drive pin not excessively worn or bent and free of gouges.
All guards in place and secure.
All fasteners tight and secure.
Air filter / oil filter (hydraulic or engine) clean.
Flush clean water through the pump and spray the assembly every night. This prolongs the
pump and blade life.
Clean machine before starting lubrication maintenance.
Ensure machine is on solid, level ground before starting maintenance.
During lubrication maintenance ensure strict cleanliness is observed at all times.
To avoid the risk of accidents, use the correct tool for the job and keep tools clean.
The draining of engine oil is best carried out when the oil is warm NOT hot.
Any spilled oil must be cleaned up immediately.
Use only clean containers for oil and only CLEAN, FRESH oils and grease of correct grade.
Contaminated Water / Fluids / Oil / Filters Must Be Disposed of Safely.