Make ground wire a little longer than oth-
ers. (More than 2-3/8 in. [60 mm])
2-1. ATTACHING THE INSTALLATION PLATE
 )LQGDVWXGLQWKHZDOOWRDWWDFKLQVWDOODWLRQSODWHKRUL]RQWDOO\E\WLJKWHQLQJWKH¿[LQJ
VFUHZV¿UPO\
To prevent installation plate (1) from vibrating, be sure to install the attachment screws in
the holes indicated in the illustration. For added support, additional screws may also be
installed in other holes.
When the knockout is removed, apply vinyl tape to the knockout edges to prevent damag-
ing the wires.
When the indoor unit is to be attached to a concrete wall using recessed bolts, secure
installation plate (1) using 7/16 in. x 13/16 in. · 7/16 in. x 1 in. (11 mm × 20 mm · 11 mm
× 26 mm) oval hole (17-3/4 in. [450 mm] pitch).
 ,IWKHUHFHVVHGEROWLVWRRORQJFKDQJHLWIRUDVKRUWHURQH¿HOGVXSSOLHG
2-2. DRILLING
1) Determine where the holes will be located on the wall.
2) Drill a ø 3 in. (75 mm) hole. The outdoor side should be 6/32 to 9/32 in. (5 to 7 mm) lower
than the indoor side.
3) Insert wall hole sleeve (C).
2-3. CONNECTING WIRES FOR INDOOR UNIT
Note:
When the indoor unit is powered from the outdoor unit, depending on local code, a discon-
nect switch needs to be installed to a power supply circuit.
1) Remove the panel assembly. (Refer to 5-1.)
2) Place the upper part of the indoor unit on the installation plate.
3) Remove corner box R and electrical cover.
4) Remove display panel, conduit cover and conduit plate.
5) Attach conduit pipe (for rear piping) / elbow joint (for right, left, or downward piping) to
conduit plate with lock nut. The thread of the installed conduit pipe / elbow joint appearing
inside should be less than 3/8 in. (10 mm). (Fig. 1) Elbow joint should appear less than
1-3/16 in. (30 mm) outside. (Fig. 2)
6) Process the end of ground wire (Fig. 3). Connect it to the ground terminal of electrical
parts box.
7) Process the end of indoor/outdoor unit connecting wire (A) (Fig. 3). Attach it to the terminal
block. Be careful not to make mis-wiring. Attach the wire to the terminal block securely
so that its core cannot be seen, and no external force affects the connecting section of
the terminal block.
8) Firmly tighten the terminal screws. After tightening, verify that the wires are tightly fastened.
9) Reinstall conduit plate, conduit cover and display panel.
10) According to the piping direction, remove the shaded part of the corner box L (Fig. 4) or
corner box R (Fig. 5). Reinstall electrical cover, corner box R and panel assembly.
Lead
wire
19/32 in.
(15 mm)
Less than 3/8 in.
(10 mm)
Conduit plate
Conduit pipe or
elbow joint
Lock nut
Elbow joint
(for right, left, or downward piping)
Less than 1-3/16 in.
(30 mm)
Fig. 1 Fig. 2
Fig. 3
Fig. 4
Corner box R
Remove corner
box R for piping
on right side of
unit.
Remove corner
box R for piping
on bottom side
of unit.
Fig. 5
Box
Corner
box L
Remove corner box L for piping
on bottom left side of unit.
Remove corner
box L for piping on
left side of unit.
Remark:
* A disconnect switch should be
required.
Check the local code.
** Use a ring tongue terminal in
order to connect a ground wire
to terminal.
Power supply
208/230 V AC,
1 phase 2 wires,
60 Hz
INDOOR UNIT
Terminal block
208/230 V AC
,
1 phase, 60 Hz
OUTDOOR
UNIT
Terminal
block 1
Ground
Grounding terminal**
Grounding
terminal**
Disconnect
switch*
Conduit plate
Level
Installation plate (1)
Center of
ø 3 in. (75 mm)
hole
5 1/2 in.
(140 mm)
or more
5-7/8 in.
(149 mm)
or more
2 1/8 in. (55 mm) or more
4 5/8 in. (118 mm) or more for left
and left back piping (using spacer)
Ceiling
Wall
Wall
Fixing screw (2)
* Same for left hole.
Insert
the
scale. *
Align the
scale with
the line. *
4 in.
(100 mm)
Connect wires to the appropriate terminals
For future servicing, leave some slack in the connecting wires.
Fixing screw
Indoor terminal
block
Conduit plate
Conduit pipe
(for rear piping)
Lock nut
Elbow joint
(for right, left, or downward piping)
or
Electrical box
Conduit cover
Display panel
Remove corner box R for
conduit pipe on bottom
side of unit.
Electrical cover
Wall
Outdoor side
6/32-9/32 in.
(5-7 mm)
ø 3 in.
(75 mm)
Grounding
terminal
Grounding terminal**
2. INDOOR UNIT INSTALLATION