1-4. INSTALLATION DIAGRAM
Outdoor unit installation
2-1/8 in. (55
mm) or more/
4-5/8 in. (118 mm)
or more for left and
left back piping
(using spacer)
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate 1
(2)
Attachment screws for the installa-
tion plate
4 × 25 mm
7
(3) Wireless remote controller 1
(4)
Felt tape
(For left or left-rear piping)
1
(5) Remote controller holder 1
(6)
Screws for the remote controller
holder
3.5 × 16 mm (Black)
2
(7) Battery (AAA) for (3) 2
(8) $LUFOHDQLQJ¿OWHU 2
FIELD-SUPPLIED PARTS
(A)
Indoor/outdoor unit connecting wire *1
1
(B) Extension pipe 1
(C) Wall hole sleeve 1
(D) Wall hole cover 1
(E) Pipe attachment strap
2 to 5
(F) Screw for (E) 4 × 20 mm
2 to 5
(G) Piping tape 1
(H) Putty 1
(I)
Drain hose
(or soft PVC hose, 19/32 in. [15
mm] inner diameter or hard PVC
pipe VP16)
1 or 2
(J) Refrigerant oil 1
(K) Power supply cord *1 1
Units should be installed by licensed contractor
according to local code requirements.
Note:
*1 Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.
Unit: inch
Unit: mm
5-7/8 in.
(149 mm)
or more
After the leak test, apply insulating
material tightly so that there is no gap.
33-1/16
13-3/4~14-5/8
19-11/16
Air inlet
6-7/8
15-3/8
13
Air outlet
2-3/8 x 13/16 slot 1-9/16
40
840
175 500
Air inlet
390
330
349~371
Air outlet
2-10 x 21 slot
When the piping is to be attached to
a wall comprised of tin plate or metal
netting, use chemically treated wooden
piece 25/32 in. (20 mm) or thicker be-
tween the wall and the piping, or wrap
insulation vinyl tape 7 to 8 turns around
the piping.
To use existing piping, perform COOL
operation for 30 minutes and pump
down before removing the old air con-
GLWLRQHU5HPDNHÀDUHDFFRUGLQJWRWKH
dimension for new refrigerant.
3/8 in. (10 mm)
or more
4 in.
(100 mm)
or more
4 in.
(100 mm)
or more
14 in.
(350 mm)
or more
20 in.
(500 mm) *3
or more
5-1/2 in.
(140 mm)
or more
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain
water or damaged by frozen drain water.
Use the wall hole sleeve
(C) to prevent indoor/out-
door connecting wire (A)
from contacting metal parts
in the wall and to protect
the wiring from rodents.
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
3LSH¿[LQJEDQG
(E)
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Attach the pipe to
wall with pipe at-
tachment strap (E).
Fixing
screw (F)
*2 20 in. (500 mm) or more when front
and sides of unit are clear
clear *2
*3 When any 2 sides of left, right and
rear of unit are clear
5.9 to 7.5 ft. (1.8 to 2.3 m) from
WKHÀRRULVUHFRPPHQGHG
Air inletAir inlet
Note:
The dimensions indicated in the arrows (
) above
show the required space to guarantee performance of
the air conditioner. Install the outdoor unit where the
maximum possible space can be provided, considering
later relocation, services, or repairs.
 7KHFRROLQJKHDWLQJSHUIRUPDQFHDQGWKHHI¿FLHQF\RI
power usage may fall about 10% at the place where short
cycle is likely occur due to poor ventilation. Installing the
air outlet guide (optional) can improve performances.
If air from the outlet blows against the wall, it may cause
stains on the wall.
Do not take in the outlet air
discharged by other units directly.
15-3/4 in. or more
(400 mm or more)
39-3/8 in. or more
(1000 mm or more)