Mitsubishi MSZ-GL12NA handleiding

52 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 52
7
(2) OPERATION
Mode Condition
Intake air temperature (°F)
Indoor Outdoor
DB WB DB WB
Cooling
Standard temperature 80 67 95
Maximum temperature 90 73 115
Minimum temperature 67 57 14
Maximum humidity 78%
Heating
Standard temperature 70 60 47 43
Maximum temperature 80 67 75 65
Minimum temperature 70 60 -4 -5
3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage Guaranteed voltage (V)
Indoor unit
208/230 V
1 phase
60 Hz
Min. 187
208 230 Max. 253
3-2. OUTLET AIR SPEED AND COVERAGE
● The air coverage is the figure up to the
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed posi-
tion.
The coverag
e should be used only as a
general guideline since it varies accord-
ing to the size of the room and furniture
arranged inside the room.
Model Mode Function
Airow
(CFM)
Air speed
(ft./s.)
Coverage
(ft.)
MSZ-GL06NA
HEAT Dry 406 20.6 29.5
COOL
Dry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-GL09NA
MSY-GL09NA
HEAT Dry 406 20.6 29.5
COOL
Dry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-GL12NA
MSY-GL12NA
HEAT Dry 406 20.6 29.5
COOL
Dry 321 16.3 23.5
Wet 286 14.5 21.0
MSZ-GL15NA
MSY-GL15NA
HEAT Dry 463 23.4 33.5
COOL
Dry 420 21.3 30.5
Wet 385 19.5 28.0
MSZ-GL18NA
MSY-GL18NA
HEAT Dry 646 29.5 44.0
COOL
Dry 646 29.5 44.0
Wet 581 26.5 39.7
MSZ-GL24NA
MSY-GL24NA
HEAT Dry 738 18.0 36.9
COOL
Dry 738 18.0 36.9
Wet 661 16.1 33.2
OBH732C

Bekijk gratis de handleiding van Mitsubishi MSZ-GL12NA, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMitsubishi
ModelMSZ-GL12NA
CategorieAirco
TaalNederlands
Grootte9967 MB