Fan Speed and Airow Direction Adjustment
1
Press to select vertical airow direction. Each
press will change airow direction in the following
order:
(Auto) (1) (2) (3) (4) (Swing)
• Two short beeps will be heard from the indoor unit when set to Auto.
• Moving the horizontal vane/multi-flow vane manually can cause trou-
ble.
• The horizontal vane/multi-flow vane automatically moves in certain in-
tervals to determine its position, and then it returns to the set position.
• When the air outlet is switched between 1 flow and 2 flow, the horizon-
tal vanes may move and change their positions.
(Auto) .........The vane will be set to the most ecient airow direction.
Cool/Dry/Fan mode (2 ow) : position (2)
Cool/Dry/Fan mode (1 ow) : position (1)
Heat mode (2 ow) : position (2)
Heat mode (1 ow) : position (3)
(Manual) ..... For efficient air conditioning, select upper position for cool
mode/dry mode, and lower position for heat mode. During cool
mode/dry mode, when the vane is set to position (3) or (4), the
vane automatically moves to position (1) after 0.5 to 1 hour to
prevent water dripping.
(Swing) ....... The horizontal vane will move up and down intermittently.
Left-right airflow direction
■ To change the horizontal airow direction.
Move the vertical vane manually
before starting operation.
1
Press to select fan speed. Each press changes
fan speed in the following order:
(Auto) (Silent) (Low) (Medium) (High) (Super High)
• Two short beeps are heard from the indoor unit when set to Auto.
• Use higher fan speed to cool/heat the room quicker. It is recommend-
ed to lower the fan speed once the room is cool/warm.
• Use lower fan speed for quiet operation.
1
Press to select the air outlet(s).
When 2 ow is selected, air blows from the top and the
front of the unit. When 1 ow is selected, air blows only
from the top of the unit.
(2 ow) (1 ow)
The multi-flow vane is automatically set to the appropriate position.
Even if 2 flow is selected, air will blow only from the top of the unit in the
following conditions:
• During cool mode/dry mode: The room temperature is close to set
temperature. The air conditioner has op-
erated for 0.5 to 1 hour.
• During heat mode: The air flow temperature is low.
(During defrosting operation, start of operation, etc.)
Note:
Movement at the start of the 2 ow operation
• Cool mode/Dry mode, heat mode: It takes 0.5 to 1 minute to start the 2 ow
operation.
• Heat mode: When cold air blows out from the air outlet, the multi-ow vane
may stop moving for up to 10 minutes to make and blow out warm air.
Operation
Cool (Dry) operation Heat operation
Airow
2 ow Upward
and downward
airow
1 ow Upward
airow
2 ow Upward
and downward
airow
1 ow Upward
airow
Conditions
When the room
temperature
diers from the
set temperature
When the room
temperature is
close to the set
temperature.
Or, after
approximately 1
hour has passed
since operation
started.
When the
airow
temperature is
high.
When the airow
temperature is low.
(Examples:
During defrosting
operation
At the start of operation
When the temperature
approaches the set
temperature)
Air outlet selection
Fan speed
Up-down airflow direction