EN-3
1-3. SPECIFICATIONS
1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation.
(1) Drain hose* 1
(2) Remote controller holder 1
(3)
Fixing screw for (2) 3.5 × 16 mm
(Black)
2
(4) Pipe cover 1
(5) Band 2
(6) Battery (AAA) for (12) 2
(7) Indoor unit mounting bracket 1
(8) Fixing screw for (7) 4 × 25 mm 5
(9) Wood screw for indoor unit xation 4
(10) Washer of (9) 4
(11) Felt tape (For left or left-rear piping) 1
(12) Wireless remote controller 1
(13) Air cleaning lter 2
(14) Breaker tag 1
(15) Breaker notice 1
* Note:
The Drain hose is connected to the unit.
Units should be installed by licensed contractor according to
local code requirements.
PARTS TO BE PROVIDED AT YOUR SITE
(A) Indoor/outdoor unit connecting wire* 1
(B) Extension pipe 1
(C) Wall hole sleeve 1
(D) Wall hole cover 1
(E) Pipe xing band 2 to 5
(F) Fixing screw for (E) 4 × 20 mm 2 to 5
(G) Piping tape 1
(H) Putty 1
(J)
Drain hose
(or soft PVC hose, 15 mm inner dia. or
hard PVC pipe VP16)
1 or 2
(K) Power supply cord* 1
(L) Band (Wi-Fi interface connection only) 2
* Note:
Place indoor/outdoor unit connecting wire (A) and
power supply cord (K) at least 1 m away from the TV
antenna wire.
150 mm or below
from the oor
100 mm or more
No obstruction
100 mm or more
*1 Connect to the power switch which has a gap of 3 mm or more
when open to interrupt the source power phase. (When the
power switch is shut o󰀨, it must interrupt all phases.)
*2 Use wires in conformity with design 60245 IEC 57.
*3 Never use pipes with thickness less than specied. The
pressure resistance will be insu󰀩cient.
*4 Use a copper pipe or a copper-alloy seamless pipe.
*5 Be careful not to crush or bend the pipe during pipe bending.
*6 Refrigerant pipe bending radius must be 100 mm or more.
*7 Insulation material : Heat resisting foam plastic 0.045 specic
gravity
*8 Be sure to use the insulation of specied thickness. Excessive
thickness may cause incorrect installation of the indoor unit
and insu󰀩cient thickness may cause dew drippage.
Model
Power supply *1 Wire specications *2 Pipe size (thickness *3, *4, *5, *6)
Insulation thickness *7,*8
Rated Voltage Frequency Indoor/outdoor connecting wire Gas Liquid
MFXZ-KW25VG
230 V 50 Hz 4-core 2.0 mm
2
ø9.52 mm
(0.8 mm)
ø6.35 mm
(0.8 mm)
14 mm
MFXZ-KW35VG
MFXZ-KW50VG
ø12.7 mm
(0.8 mm)
40 mm
or less
30° or less
45 mm or more
Obstacles above
It’s possible to install
an obstacle to the
following area.
When installing outdoor units, refer to the outdoor unit installation manual.
The piping specication table does not provide a minimum line set length.
However, indoor units with connected piping length less than 3 m could produce
intermittent noise during normal system operation in very quiet environments.
Please be aware of this important information when installing and locating the
indoor unit within the conditioned space.
Cover the connection part with tape to prevent water from leaking.
After the leak test, apply insulating material tightly so that there is no gap.
Be sure to use wall hole
sleeve (C) to prevent indoor/
outdoor connecting wire (A)
from contacting metal parts in
the wall and to prevent dam-
age by rodents in case the wall
is hollow.
When the piping is to be attached to a wall containing metals (tin plated)
or metal netting, use a chemically treated wooden piece 20 mm or thicker
between the wall and the piping or wrap of insulation vinyl tape around the
piping.
To use existing piping, perform COOL operation for 30 minutes and pump
down before removing the old air conditioner. Remake are according to
the dimension for new refrigerant.
WARNING
To avoid risk of re, embed or protect the refrigerant piping.
External damage on the refrigerant piping can be cause of re.
Indoor unit
Cut o󰀨 the extra
length.
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Fix the pipe to
wall with pipe xing
band (E).
Pipe xing band
(E)
Fixing screw
(F)
Wall hole
sleeve (C)