ZEROING PROCESS
2
3
1
4
5
6
7
1. Cover cap of the elevation adjustment
2. Cover cap of the lateral adjustment
3. Adjustment turret (elevation)
4. Adjustment turret (lateral)
5. Reference mark for zero setting
6. Retaining screw with coin slot (elevation)
7. Retaining screw with coin slot (lateral)
Adjustment turrets with screw-on caps
The RS-6 scopes feature flat adjustment turrets with screw
caps (with the exception of the elevation adjustment turret of
the 3-18x56 BDC).
To zero in, first unscrew the elevation and lateral adjustment
caps (1 and 2). Below this there are rotatable adjustment
turrets (3 and 4) with a scale and a reference point for
the zero setting (5). Each click and scale graduation of the
adjustment turret means a change in the point of impact of 1
cm at 100 m. A clockwise turn shifts the target downwards or
to the left. A counterclockwise turn shifts the target upwards
or to the right.
When the desired zero position is set, loosen the retaining
screw (6 and 7) with a coin until the turret rises far enough
to expose the red O-ring (see picture-in-picture). Turn the
adjustment turret so that the zero mark matches the reference
mark on the turret base and secure with your fingers. Then
tighten the retaining screw again with a coin.