Midea RSJ-15 handleiding
Handleiding
Je bekijkt pagina 39 van 48

37
Something about self-protection of unit
When the self-protection happens, the system will be stopped and start self-check, and
restart when the protection resolved. When the self-protection happens, the will flash
and error code will be shown at water temperature indicator. But the and error code
does not disappear until protection resolved.In the following circumstance, self-protection
may happen: Air inlet or outlet is blocked;The evaporator is covered with too much dust;
Incorrect power supply (exceeding the range of 220-240V).
When Error happened
Error phenomenon shooting
If some normal errors happen, unit will automatically shift to E-heater for emergent
SHW supply, please contact qualified sta to repair.
If some sever error happen, unit will not start, please contact qualified sta to repair.
1)
2)
Error
phenomenon
Possible reason solution
Cold water
tapped out and
display screen
extinguished
No hot water
tapped out
Water leakage
Hydraulic pipeline joints
are not sealed well.
Bad connection
between power supply
plug and socket;
Setting water
temperature too low;
Temp. sensor broken;
PCB of indicator broken.
1. Plug in;
2. Setting water temp. higher;
3. Contact service center.
Waiting for public water
supply recover;
Waiting for inlet water
pressure increase;
Open water inlet valve.
Check and reseal all joints.
Public water supply
ceased;
Cold water inlet pressure
too low (<0.15 MPa);
Cold water inlet valve
closed.
1.
2.
3.
1.
2.
3.
1.
2.
3.