Why sometimes the buttons are
unavailable?
A: if there is no operation on panel for
60s, unit will lock the panel, shows " ",
to unlock the panel, please press the
" "+ " "button for 2 seconds.
36
TROUBLE SHOOTING
Non-error tips
Why compressor can't start immediately
after setting?
Unit will wait for 3 min to balance the
pressure of system before start compressor
again, it's a self protection logic of unit.
Why sometimes the temperature shown on
the display panel decreased while unit is
running?
When the upper tank temperature is much
higher than the bottom part, upper part hot
water will be mixed by the bottom cold
water which is continually flow from inlet
tap water so that will decrease the upper
part temperature.
Why sometimes the temperature shown on
the display decreased but unit still keep
closed?
to avoid unit ON/OFF frequently, unit will
activate heat source only when bottom
tank temperature is lower than setting
temperature.
Why sometimes the temperature shown on
the display will decreased dramatically?
Because tank is pressure-bearable type, if
there is massive hot demand, hot water will
quickly tapped out from upper part of tank
as well as cold water will quickly tapped
into bottom part of tank, if the cold water
surface emerge the upper temperature
sensor, temperature shown on the display
will decreased dramatically.
Why sometimes the temperature shown
on the display is decreased a lot, but there
is still a mount of hot water can be
tapped?
Because the upper water sensor is located
on the upper 1/4 tank,when tapping hot
water out, it means there is at least 1/4
tank of hot water available.
Why sometimes there is some water
flowed from drainage pipe ofsafety
valve?
Because the tank is pressure-bear-
able one, when water is heated
inside the tank, water will expand,
so the pressure inside of tank will
increase, if pressure goes up more
than 1.0Mpa, safety valve will
activate to relief the pressure and
hot water drop will be
discharged correspondingly. If
water drop is continually discharged
from safety valve drainage pipe, it is
abnormal, please contact qualified
stu to repair.
Q:
A:
Q:
A:
Q:
A:
Q:
A:
Q:
A:
Q:
A:
Q:
Why sometimes unit shows "EHLA" on display
?
When the unit does not have electric heating
function, the heat pump available running
ambient air inlet range is -7-43°C, if ambient air
inlet temperature is out of range, system will
show above-mentioned signal to let user notice
it.
Q:
A:
A: