Defrosting During Water-heating
In heat pump running period, if the evaporator frosted in lower ambient temperature,
the system will defrost automatically to keep eective performance (about 3~10min).
At defrosting time, the fan motor will stop, but compressor will still run.
COP
COP varies at dierent ambient temperature. Normally lower ambient temperature
result in longer heat-up time because of lower eective performance.
When ambient temp below 2˚C, heat pump and E-heater will take dierent portions
of heating capacity, generally the lower of ambient temperature, the lower portion of
heat pump will contribute as well as the higher portion of E-heater will provide
more detail please refer to Table.
About TCO (Thermal-cuto)
The power of E-heater will be automatically shut-o or turn on by TCO.If the water
temperature is higher than 85˚C, the TCO will automatically shut o the power of
compressor and E-heater. After that it needs to be reset manually.
Restart After a Long Term Stop
When the unit is restarted after a long term stop (trail running included), it is normal
that outlet water is unclean. Turn the tap on and the water will be flushed clean.
Heat Source Shift
4)
The default heating source is heat pump.If ambient temperature range is
out of heat pump operating range, heat pump will stop running, the unit
will shift automatically to activate E-heater and show on the display,
then if the ambient temperature goes into the running range of heat
pump again, it will stop E-heater and shift automatically to heat pump
again, and will be extinguished.
If the target setting water temperature is higher than Maximum temperature
(Heat pump), the unit will activate heat pump firstly to the Maximum temperature,
then stop heat pump, activate E-heater to continually heat water to the target
temperature.
NOTE
E-heater will be activated once by pressing for economy mode or hybrid
mode, if want to apply E-heater again, please push forced E-heating Combination
button again.
If only use E-heater, about 150 liters water will be heated, so set higher target
water temperature if ambient temperature is out of heat pump running range.
Time, hour
Heat Up Time within Different Temperature (190L)
Capacity, W
Capacity within Different Temperature (190L)
If manually activate the E-heater running when heat pump running, E-heater
and heat pump will work together until the water temperature gets to target
temperature. So to increase recovery rate, please manually activate E-heater.