2. About Running
System Structure Figure
Unit has two kinds of heat sources: Heat pump (compressor) and electric
heater.The unit will automatically select heat sources to heat water to the
target temperature.
1)
Water Temperature Display
The temperature shown on the display depends on the upper sensor. It is
normal that the display temperature has reached to target temperature but
compressor still running, because the lower water temperature does not
meet to target temperature.
2)
Three modes (Economy Mode, Hybird Mode and E-heater mode ) can be
selected by pressing the button.
3)
Running Temperature Range
Setting water temperature target range: 55~ 70
˚
C.
E-heater running ambient temperature range: -20~ 45
˚
C.
Heat pump running ambient temperature range: -7~ 43
˚
C.
Water temperature limits:
Tank
Electric heater
Water inlet
Water outlet
Temperature sensor(T5L)
T4<-7
70 70 70 70 70 70
5850 6045
-- --
70 70 70
58
-- --
-7≤T4<-2
RSJ-15/190RDN7-L2
-2≤T4<0 0≤T4<38
Ambient
temp.(T4)
Model
Max.Temp.
(Heat pump)
Max. Temp.
(E-heater)
38≤T4<43
43≤T4
70 70 70 70 70 70
5850 6045
-- --
T4<-7 -7≤T4<-2
RSJ-23/300RDN7-L2
-2≤T4<0 0≤T4<38
Ambient
temp.(T4)
Model
Max.Temp.
(Heat pump)
Max. Temp.
(E-heater)
38≤T4<43
T4≥43