Electric Connection
The power supply should be hard wired.
Power supply circuit should be earthed eectively. The wiring must be performed
by professional technicians in accordance with national wiring regulations and the
circuit diagram below.
An all-pole disconnection device which has at least 3mm separation distance in all
pole and a residual current device (RCD)with the rating of above 10mA shall be
incorporated in the fixed wiring according to the national rule.
Set the electric leakage protector according to the relevant electric technical
standards of the state.
The power cord and the signal cord shall be laid out neatly and properly without
mutual interference or contact the connection pipe or valve.
After wire connection, check it again and make sure of connection before power
is turned on.
The unit is equipped with a cord without a plug that enables connection to power
via a weatherproof power outlet.
CAUTION
1. Specifications of Power Supply
2.5
30/252kW
3kW
30 mA
0.1sec
Creepage Breaker
Earth cord (mm
2
)
Manual Switch(A) Capcity/Fuse(A)
Model Name
Power Supply
Min. Diameter of Power
Supply cord (mm
2
)
220-240V50Hz
RSJ-15/190RDN7-L2
2.5
2.5
40/30
30 mA
0.1sec
Creepage Breaker
Earth cord (mm
2
)
Manual Switch(A) Capcity/Fuse(A)
Model Name
Power Supply
Min. Diameter of Power
Supply cord (mm
2
)
220-240V50Hz
RSJ-23/300RDN7-L2
2.5
WARNING
The unit in must be installed with an RCD near the power supply and must be
eectively earthed.
2. Electric leakage protector
L
N
GND
Power Cable
RCD
Power Supply