Only for the North American
(D)
Indoor unit
Outdoor unit
Air switch
Air switch
(purchased seperately)
(purchased seperately)
(purchased seperately)
Outdoor unit power wires
Indoor & Outdoor
connective wires
(C)
Indoor unit
Outdoor unit
Air switch
(purchased seperately)
Air switch
(purchased seperately)
(purchased seperately)
Indoor unit power wires
Indoor & Outdoor
connective wires
Outdoor unit power wires
(B)
Indoor unit
Outdoor unit
Air switch
(purchased seperately)
(purchased seperately)
Indoor unit power wires
Indoor & Outdoor
connective wires
(A)
Indoor unit
Outdoor unit
Air switch
(purchased seperately)
(purchased seperately)
Outdoor unit power wires
Indoor & Outdoor
connective wires
NOTE ON AIR SWITCH
NOTE: The cographs are for explanation purpose only. Your machine may be slightly dierent.
The actual shape shall prevail.
WARNING
OUTDOOR UNIT WIRING
Before performing any electrical or wiring work, turn o the main power to the system.
Prepare the cable for connection1.
a. You must first choose the right cable
size. Be sure to use H07RN-F cables.
NOTE: In North America, choose the cable type
according to the local electrical codes and regulations.
When the maximum current of the air conditioner is more than 16A, an air switch or leakage
protection switch with protective device shall be used(purchased seperately). When the
maximum current of the air conditioner is less than 16A, the power cord of air conditioner shall
be equipped with plug (purchased seperately). In North America,the applicance should be
wired according to NEC and CEC requirements.