Error Code
Unit
Action
Causes Explanation
E12
Overflowing.
Unit will close
valve and stop
with Error code
display
Restart
Some time just restart the unit can
solve the problem.
Water inlet
valve
(The voltage on
the water inlet
valve is normal)
If the washer is overflowing, the
water inlet valve has failed. Replace
it.
Water level
sensor or
control switch
(No voltage on
the water inlet
valve)
A water lever control switch
controls how much water enters the
washing machine by PCB. If the
water level control switch is
defective, or more commonly, if the
small air pipe attached to the air
bell restricted, The switch will not
be able to close the electrical
contacts to the washer fill valve.
CHECK THE AIR PIPE
CHECK THE WATER LEVERL SENSOR
CHECK THE PCB and the inner wire
between PCB and the sensor