WARNING
The complete electrical rating of your new room air conditioner is stated on the serial
plate. Refer to the rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire
hazards, proper grounding is important. The power cord is equipped with a
three-prong grounding plug for protection against shock hazards.
The air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time
delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner without side protective cover in place.This could result in
mechanical damage within the air conditioner.
Do not use an extension
cord or an adapter plug.
Electrical Information
Operation of Current Device
(Applicable to only units with a current detection device)
The power supply cord contains a current device that senses damage to the power
cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST
button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. On some products,
this is also indicated by a light on the plug head.
NOTICE
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST
button is pushed or if it cannot be reset. A new one can be obtained from the
product manufacturer.
If power supply cord is damaged, it cannot be repaired. It MUST be replaced by
one obtained from the product manufacturer.
NOTE: This air conditioner can not be as a primary heat source; This air
conditioner is designed to be operated under the following conditions:
Cooling
operation
Outdoor
temp:
Indoor
temp:
64-109 /18-43 (64-125 /18-52
for special tropical models)
60-90 /
16-32
• Performance may be reduced outside of these operating temperatures.
-
ing from cool to fan and back to cool. This prevents damage from occurring to the
compressor.
• The relative humidity of the room should be less than 80%. If the unit is used in a
condition with a relative humidity over 80%, there will be condensed water on the
surface of the unit.