5.3 System Power O
Power O Inverter and Bidirectional DC/DC Unit
Step 1: Turn the PV switch between the inverter and the PV panels to OFF.
Step 2: Turn the AC switch between the inverter and the grid to OFF.
Step 3: Turn the DC switch on the bidirectional DC/DC unit to OFF.
Battery Power O
The battery will automatically power o within 3 minutes after system
power-o (when the DC switch on the bidirectional DC/DC unit is set to OFF), or
by pressing the black start button on the bidirectional DC/DC unit for 30 seconds.
All LED indicators on the bidirectional DC/DC unit turn o. After the system has
been powered o for five minutes, ensure all residual energy in the battery is
discharged before performing maintenance.
Step 3 Turn the AC switch between the inverter and the grid to ON. Observe
the “COM” LED indicator on the bidirectional DC/DC unit is lighted, “DC” and “AC”
LED indicator on the inverter are lighted.
Step 4 Start Operation. After power on the system, turn on the EMS by
tapping "Maintenance" in the goMslar App and turning on the "EMS on/o"
switch. Confirm the startup begins.