Midea H1-(5-20)-E0 handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 15 van 32
3.4 Installation Space
To ensure sucient space for installation and heat dissipation, reserve enough
space around the energy storage system. The requirements are as follows:
Install the four foot cups under the base, align the base with the wall, and ensure
that the base is 77mm~92mm away from the wall surface. Adjust the four foot
cups of the base until it is level.
Figure. 3-1 base installation diagram
3.5 Energy Storage System Installation
Step1: Base installation
RUN COM 25% 50% 75% 100%
300-600mm
300-600mm
≥300mm
wall
77-92mm
foot
14
• The operation and service life of the battery depend on the operating
temperature. Install the battery at a temperature equal to the ambient
temperature or in a better environment.
• The operating temperature of the battery system ranges from -20°C to +55°C. If
the battery system is installed in a cold environment, the built-in thermal control
system starts to heat the battery to achieve better performance. The heating
process consumes rechargeable power, which reduces the system energy
eciency in cold weather.
• If the battery system is stored in a cold environment (for example, 0°C) before
installation, the battery system needs some time (< 2 h) to heat up before it can
be charged. You are advised to place the battery system in a warm place before
installation to facilitate commissioning.