UNDERSTANDING AN AUTOPING CONFIGURATION
This section takes you through an AutoPing configuration where your RackLink reboots a
modem/router in the evet that its Internet connection stops working.
NOTE:
A proper AutoPing configuration prevents cyclic outlet rebooting. Cyclic outlet rebooting is the
result of AutoPing settings not taking the modem/router’s start-up time into account. This
results in your RackLink continuously turning the controlled outlet on and off.
Understand that email notifications are not received in the event that your Internet connection
goes down. Instead, a recovery notification is sent when the connection is reestablished. Refer
to the log entry for more information about when the actual failure occurred. For more
information, see “Viewing Status Log Information” on page 37.
Connecting Your Equipment
This picture shows the following connections you should make to your equipment:
Connect your modem/router’s (black box above the RackLink) power cable into a controlled
outlet on the RackLink.
Connect your RackLink’s Ethernet cable (blue) into switch port 1 on the modem/router.
Connect your modem/router to the Internet (yellow cable).