4.3.2 Data payload
Message type=8
Data Length=10 bytes
Output Rate=1Hz
Analog Channel Type: Unsigned Int (16 bits)
CH4 (4 bits), CH3 (4 bits), CH2 (4 bits), CH1 (4 bits)
0=Off
1=Pressure
2=Temperature
3=Current
5=Volts
Analog Channel 1: Signed Int (16 bits)
Pressure in instrument units
Temperature in Degrees C
Current in 0.1A
Volts in 0.1V
Analog Channel 2: Signed Int (16 bits)
Pressure in instrument units
Temperature in Degrees C
Current in 0.1A
Volts in 0.1V
Analog Channel 3: Signed Int (16 bits)
Pressure in instrument units
Temperature in Degrees C
Current in 0.1A
Volts in 0.1V
Analog Channel 4: Signed Int (16 bits)
Pressure in instrument units
Temperature in Degrees C
Current in 0.1A
Volts in 0.1V