10
C5 4 Series Insulation Armour
Plus
Hot Food Holding Cabinets
L01-581
Armour Panel Cleaning
Use soft cloth, mild soap water solution to clean lightly-soiled surfaces. Then wipe dry with a clean, soft cloth. For heavi-
ly-soiled areas, use a soft brush and solvent or emulsion-based cleaner. Always ensure the cleaner is recommended for
use on plastics and follow any special instructions from the manufacturer.
BASIC TROUBLESHOOTING
WARNING: Only factory approved service agents must attempt to service, repair or replace electrical components,
wiring or power cord.
1. Controls do not work (no indicator lights):
t Check that the cabinet is plugged-in.
t Check that the outlet has power.
t Check that the power switch is in the “On position.
t Check the cabinet wiring from the power cord to the power switch and to the thermostat.
2. Temperature too hot:
a. During initial pre-heat, cabinet may overshoot set point.
b. If displayed temperature exceeds 220°F (104°C):
)SV^LY^PYPUNPZMH\S[`VYKPZJVUULJ[LK)SV^LYULLKZYLWSHJPUN
;OL[OLYTVZ[H[TH`OH]LMHPSLKHUK[OL[OLYTHSJ\[V\[KL]PJLPZJVU[YVSSPUN[OL[LTWLYH[\YL
;OLYTHSJ\[V\[KL]PJLTH`OH]LMHPSLK
3. Temperature too low:
a. The cabinet may still be in pre-heat or recovering from the door being opened.
b. Door(s) is not closed or sealing properly.
c. Worn out door gaskets. Replace gaskets.
d. Blower is not circulating air:
)SV^LY^PYPUNPZMH\S[`VYKPZJVUULJ[LK
4. No heat generated
a. If the heat indicator light is on but the cabinet does not draw approximately 12 amps for 120V units and 6 amps
for 220-240V units.
(PYOLH[LYLSLTLU[TH`ILMH\S[`
;OL^PYPUN[V[OLHPYOLH[LYLSLTLU[TH`ILMH\S[`VYKPZJVUULJ[LK
;OLYTVZ[H[TH`ILMH\S[`
;OL[OLYTHSJ\[V\[TH`ILVWLUVYOH]LHU`KPZJVUULJ[LK^PYLJVTPUN[VP[VYNVPUNMYVTP[[V[OLLSLTLU[
b. If the heat indicator light does not come on, the thermostat may be faulty.
;OLOV[)32^PYLTH`UV[ILJVUULJ[LKMYVT[OL[LYTPUHSISVJR[V[OL[OLYTVZ[H[
5. Indicator light is not working:
t It is rare that an indicator light is defective but it is possible. The thermostat contacts may not be closing and
therefore the heater element is not being energized. Check the thermostat and indicator light and their respective
wiring.