Megger EVX100 handleiding
Handleiding
Je bekijkt pagina 10 van 24

www.megger.com
EVX100
10
Operation
4.1 Battery status and charging
NOTE : The EVX must be fully charged before use.
If the EVX100 is fully charged the LED will flash Green, Yellow or Red every 10 seconds
indicating battery status, as below:
Green: 100% to 50% charge remaining
Yellow: 50% to 20% charge remaining
Red: <20% charge remaining
Holding down the button on the top of the EVX100 will also show battery status.
4.2 Charging the EVX100
NOTE : The EVX100 will only charge over an ambient temperature range of 0 ºC to 45 ºC.
Charging the EVX100 battery status is performed using a type C USB cable.
1. Disconnect the EVX100 from the EV charger.
2. With the EVX100 removed from the MFT-X1 the USB-C charging port is exposed. To
charge the EVX100 connect the adaptor to a suitable USB-C source.
The Charge status is indicated by the top LED.
Solid GREEN EVX100 is charged
Flashing GREEN EVX100 is charging
Red: A charging error has occurred – contact Megger
technical support
4.3 Hot keys:
Hot key functionality is a subset of those offered on the MFT-X1 under normal operating
conditions, i.e. non-EVX mode. Hot key functionality varies with the individual test modes
selected. Refer to the individual test mode below for details of hot key functions.
Hot key options can also be selected using the right rotary knob. Pre-test inspection and
verification requirements.
WARNING : The EVX100 performs live testing of the EV charger. Consequently, before
the EVX100 is connected to the EV Charger all the standard tests that would be
carried out on any newly installed circuit should be complete before the equipment is
made live.
4.4 Updating the MFT-X1 firmware
The MFT-X1 must be upgraded to the latest version of firmware to ensure the EVX100 will
operate. For full details of updating the MFT-X1 firmware visit www.megger.com/mft-x1. On
the MFT-X1 product page select the Product Support tab, then select Software and Firmware
updates from the right-hand options list. Follow the instructions to download the latest
firmware update.
NOTE : The Update process requires a micro-SD card to transfer the .BIN file to the MFT-X1.
Bekijk gratis de handleiding van Megger EVX100, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.