Handleiding
Je bekijkt pagina 18 van 26

Cool
The temperature can be set between 16°C and 32°C using the increase
and decrease buttons. The air conditioner will run until the desired
temperature is reached (the compressor will turn o, but the fan will
continue to run). If the temperature in the environment increases above the
target temperature, the air conditioner will automatically come back on.
Dry
The air conditioner will run according to the ambient temperatures below.
> 25°C: The compressor runs for 15 minutes and then stops for 3 minutes.
The fan will run continuously
25°C to 20°C: The compressor runs for 10 minutes and then stops for 3
minutes. The fan will run continuously
20°C to 15°C: The compressor runs for 6 minutes and then stops for 3
minutes. The fan will run continuously
< 15°C: The compressor will stop working and therefore stop drying. When
the temperature reaches 17°C the unit will run as per above
The air conditioner will default to low fan speed - this cannot be changed.
Temperature cannot be selected.
Note: make sure the drainage hose is attached to the central drainage port
for continuous drainage (see page 17).
Fan
The room air is circulated but not cooled. Select either High, Medium or
Low.
Heat
Only available on CH models.
The temperature can be set between 16°C and 32°C using the increase
and decrease buttons. The air conditioner will run until the desired
temperature is reached. If the temperature in the environment drops
below the target temperature, the air conditioner will automatically come
back on.
Note: the compressor will stop working straight away however the fan
may continue to run if the coil pipe temperature is detected to be above
34°C. The fan will stop running once the coil pipe temperature reaches
34°C or below.
The supply air fan will run continuously, blowing hot air out the front of
the air conditioner. The exhaust air fan, blowing hot air out the back of
the portable air conditioner, will turn on periodically as required. In certain
conditions, depending on the temperature and humidity level, the exhaust
air fan will run continuously. Both situations are normal operations.
Note: make sure the drainage hose is attached to the lower drainage port
for continuous drainage (see page 17).
[EN] 15
Bekijk gratis de handleiding van Meaco Cool Pro Series 12000, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Meaco |
Model | Cool Pro Series 12000 |
Categorie | Airco |
Taal | Nederlands |
Grootte | 2446 MB |