MDT BE-TAS86T.02 handleiding

99 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 99
Technical Manual
Glass Push-button II Smart & Push-button Smart 86 [Series .02]
MDT technologies GmbH • 51766 Engelskirchen • Papiermühle 1 • Germany
Phone: +49-2263-880 • knx@mdt.de • www.mdt.de
25
25
The following table shows the basic settings for the info display:
ETS-Text
Dynamic range
[Default value]
Comment
Colour of the
orientation LEDs in
Standby
Any colour
[White]
Setting the LED colour when used as
an orientation display.
Effects on settings of the "Standby
display during Day/Night".
with "...orientation LEDs".
Standby permanently
visible in upper keypad
not active
active
Standby can be permanently
activated here in the upper keypad
(Info - see below the table).
Time until Standby
0 … 60 s
[20 s]
Sets the time between the last touch
of a button and switching to Standby
mode.
Change Standby display
after …
1 … 60 s
[2 s]
Setting the changeover time
between the activated status
elements.
Standby display during
„Day“
no Standby
Standby in upper keypad
Standby over full screen
Display OFF / black
Setting the display behaviour of the
information screen in “Day” mode
LED behaviour in
Standby
off
Orientation LEDs
Button LEDs
LEDs A/B
Setting for how the LEDs should
behave during Standby.
Number of lines
1
2
3
Setting of how many lines are
displayed in Standby.
- 2 lines possible with "Standby in
upper keypad".
- 3 lines possible for "Standby over
full screen".
Line 1 / 2 / 3
one status element
several status elements in
alternation
two status elements
(left/right)
two status elements
(top/bottom)
Setting how the Standby display is
shown.
Several status elements in
alternation" only with line 1.
Status element
1 4
left/right
top/bottom
(for Day und
Night)
not active
Time
Time (AM/PM)
Date
Internal temperature
Status value 1 4
Status text 1 (via object 147)
Status text 2 (via object 148)
Activation of up to 4 status elements
and what they should display.
- "not active" only for
status element 2 - 4!
- "Internal temperature" only for
device with temperature sensor.
- "Status text 1/2" not available with
"two status elements (left/right)".